CESSNA 414 near Leadville, CO — 2024-07-04
- Date
- 2024-07-04
- Location
- Leadville, CO, USA
- Airport
- LXV
- Aircraft
- CESSNA 414
- Registration
- N1652T
- Category
- Airplane
- Highest injury
- None
- Fatalities
- 0
- Phase of flight
- Landing
Probable cause
A loss of brake fluid for reasons that could not be determined, which resulted in a loss of braking effectiveness during landing.
NTSB narrative
The pilot reported that the airplane’s brake system operated normally during the startup, taxi, and takeoff; however, while landing at the destination airport, he attempted to apply the brakes; however, there was no pressure on the brake pedals and no braking was available. There was also no pressure available on the co-pilot’s brake pedals. The airplane rolled the length of the runway. The pilot attempted to turn onto the perpendicular taxiway at the end of the runway, but the airplane departed the pavement and the nose landing gear collapsed. The nose landing gear trunnion and wheel well structure sustained substantial damage during the accident sequence. An examination of the brake system revealed that the left brake master cylinder was nearly empty and no pressure from the brake pedal to the wheel caliper was available. The right brake master cylinder contained about 1/4-inch of fluid remaining. Pressure to the wheel caliper was obtained with about three-quarter deflection of the brake pedal. The brake lines and calipers did not exhibit any evidence of leakage, and free movement of the caliper pistons was observed. Both the left and right brake linings exhibited minimal remaining thickness with signs of overheating. Airplane maintenance records noted that the landing gear was worked on during the most recent annual inspection, which was completed about two months before the accident. The pilot reported that the airplane had flown about 40 hours since the inspection. The mechanic who conducted the annual inspection reported that the brakes were inspected and no anomalies were observed at that time. Although the runway excursion was a result of the loss of brake fluid, the exact reason for the loss of brake fluid during the flight could not be determined.
Analysis
- Primary failure mode
- Mechanical failure
- First missed decision gate
- Pilot could have checked brake fluid levels before the flight.
NTSB coding
Evidence available
- Photos
- 5 docket documents
Docket documents5
Related mishaps
- CESSNA A185F
2026-06-27 · Angel Fire, NM
- CESSNA 180H
2026-06-21 · Port Angeles, WA
- CESSNA 140
2026-06-01 · Pasco, WA
- EAA Acro Sport II
2026-05-31 · Sheridan, AR
- PITTS SPECIAL S-1S
2026-05-29 · Bartlesville, OK
- GULFSTREAM AEROSPACE CORP GVII-G600
2026-05-27 · Birmingham, AL