SWEARINGEN SA227 TT near Houston, TX — 2018-01-19
- Date
- 2018-01-19
- Location
- Houston, TX, USA
- Airport
- EFD
- Aircraft
- SWEARINGEN SA227 TT
- Registration
- N6UP
- Category
- Airplane
- Highest injury
- None
- Fatalities
- 0
- Phase of flight
- Climb
Probable cause
The failure of the left starter relay during engine start, which resulted in a loss of electrical and battery power during the flight and led to a forced landing with the nose landing gear not fully extended, causing substantial damage to the engines.
NTSB narrative
During a corporate flight, as the pilots climbed the airplane to flight level 180, both electrical generators failed and would not reset. The pilots attempted to troubleshoot the problem but could not regain electrical power. The airplane's battery power was rapidly deteriorating, so the pilots declared an emergency and diverted to the nearest airport. Due to the loss of electrical power, the pilots lost communications and had to manually extend the landing gear. They could not verify, with air traffic control tower personnel, if the landing and nose gear were extended and locked. The pilots made a forced landing with the nose landing gear not fully extended, causing the airplane to skid on the forward fuselage after touchdown and substantially damaging the engines. Postaccident examination of the airplane revealed the right generator current limiter had failed. A mechanic connected a battery to the airplane, and the left propeller immediately began to rotate. The mechanic determined that there was uncommanded voltage to the left starter, which was caused by a failure of the left starter relay when the engine was started before the flight. During the flight, the right generator was managing all of the airplane's electrical load, the cumulative electrical load exceeded the capacity of the right generator current limiter, and the generator failed. At that point, the airplane's electrical load was only being supplied by battery power, which was quickly depleted. Postaccident examination of the nose landing gear did not identify a mechanical reason to explain why the nose landing gear did not extend during the pilots' emergency landing gear extension procedure.
Analysis
- Primary failure mode
- Mechanical failure
- First missed decision gate
- Pilots could have aborted the flight after electrical issues were identified.
NTSB coding
Evidence available
- 4 docket documents
Docket documents4
Related mishaps
- CESSNA P210
2024-05-16 · Daggett, CA
- BEECH 95-B55 (T42A)
2022-11-03 · Athens, GA
- AGUSTA AW139
2022-09-24 · Houma, LA
- KUYKENDALL CHARLES LANCAIR IV
2021-07-28 · Indian Springs, NV
- MOONEY M20F
2021-07-22 · New Albany, MS
- PIPER PA32R
2020-11-20 · Canon City, CO