Pilot Debrief

SWEZEY T/MOLNAR D VANS RV-10 near Ridgeland, SC — 2010-05-07

Final reportERA10LA256
Sign in to save
Date
2010-05-07
Location
Ridgeland, SC, USA
Airport
3J1
Aircraft
SWEZEY T/MOLNAR D VANS RV-10
Registration
N110TD
Category
Airplane
Highest injury
Serious
Fatalities
0
Phase of flight
Landing

Probable cause

An explosion and fire of unknown origin during taxi from landing. Contributing to the accident was the builder's noncompliance with the manufacturer's suggested designed fuel system.

NTSB narrative

According to the pilot, while on short final he smelled fuel. While taxiing off the runway after landing, the passenger opened the door to ventilate the airplane. Immediately after opening the door, the cabin was engulfed in an intense fire, which blew out the windows. The pilot said that it was similar to a "vapor fire." The occupants exited the airplane and subsequently the airplane exploded a second time and was consumed by fire. A Federal Aviation Administration inspector reported that the majority of the airplane was consumed by fire. Examination of the airplane revealed the fuel pump had automotive type rubber hoses and quick clamps used to attach the hoses to right angle fittings, instead of the fuel lines made of soft aluminum tubing provided by the kit manufacturer. Although it could not be determined if a fuel leak was caused by a faulty hose or clamp, it is likely that fuel had leaked from the builder's redesigned fuel system. It is also likely that a spark was generated by either the flap motor or from a static discharge. The pilot reported that he normally raises the flaps after clearing the runway, but could not recall if he had raised the flaps just prior to the first explosion.

Analysis

Primary failure mode
Fuel management
First missed decision gate
Pilot could have checked for fuel leaks before landing.

NTSB coding

Evidence available

  • Photos
  • 6 docket documents
View NTSB final reportView NTSB docket

Docket documents6