Pilot Debrief

REMOS AIRCRAFT GmbH Remos GX near Taylor, AZ — 2023-12-06

Final reportWPR24FA052
Sign in to save
Date
2023-12-06
Location
Taylor, AZ, USA
Airport
TYL
Aircraft
REMOS AIRCRAFT GmbH Remos GX
Registration
N449RA
Category
Airplane
Highest injury
Serious
Fatalities
0
Phase of flight
Taxi

Probable cause

The pilot’s decision to attempt takeoff with frost covering the airplane’s wings, which led to an exceedance of the airplane’s critical angle of attack and an aerodynamic stall.

NTSB narrative

The pilot of the light sport airplane was preparing to depart for a cross-country flight. A witness reported that when he arrived at the airport that morning, he saw the airplane on the parking ramp, not moored down, and the engine was running. As the airplane taxied through the ramp area, he saw that it was covered with frost. Soon after the witness had gone inside the airport office, he was notified from an airplane flying over the airport that an airplane had crashed on the runway. A photo of the accident site minutes after the accident revealed that the upper surfaces of the horizontal stabilizers were covered in frost. Postaccident examination of the airframe and engine revealed no evidence of any preimpact mechanical malfunction or failure that would have precluded normal operation. Based on the witness’s statement and photo evidence, the airplane likely had frost-contaminated wings, which the pilot did not remove before takeoff. His subsequent rotation of the airplane during takeoff with its lift capability degraded due to contamination of its flying surfaces resulted in exceedance of the airplane’s critical angle of attack, an aerodynamic stall, and subsequent impact with the ground.

Analysis

Primary failure mode
Environmental
First missed decision gate
Pilot should have cleaned frost off the aircraft before taxiing for takeoff.

NTSB coding

Evidence available

  • Photos
  • 11 docket documents
View NTSB final reportView NTSB docket

Docket documents11

Related mishaps