Pilot Debrief

BELL OH-58A near Arvin, CA — 2009-04-30

Final reportWPR09CA220
Sign in to save
Date
2009-04-30
Location
Arvin, CA, USA
Aircraft
BELL OH-58A
Registration
N175SJ
Category
Helicopter
Highest injury
None
Fatalities
0
Phase of flight
Maneuvering

Probable cause

The pilot’s failure to maintain clearance from wires during aerial application maneuvers.

NTSB narrative

The pilot was on the last local aerial application flight of the day. Prior to starting the job, he flew above and around the field to check for obstructions and power lines. The field had numerous electrical feeder wires, with north-south power lines on the west and east ends of the 1/2-mile-long field. This application required the material be applied while making east-west passes above the feeder wires and oil pumps. Upon maneuvering onto the last eastbound pass, he applied aft cyclic to climb above the location of feeder wires. Several seconds later, he felt a sudden jarring and vibration emitting from the rear portion of the helicopter. He felt that he had possibly struck a wire that he did not see, and continued flying the helicopter in an eastbound direction to perform an emergency landing. As he began slowing, the front of the helicopter began yawing to the right in a southeast direction and it was headed towards a triple strand of east-west power lines and a small oil pump 25 feet south of the electrical lines. In anticipation of a second wire strike, he closed the throttle and began an autorotation prior to the helicopter striking the east-west power lines. It came to rest in an upright position facing in a southwest direction. He could hear the engine operating and performed emergency engine shutdown procedures. Visual examination revealed that the tail rotor made contact with the first set of power lines and separated along with its gearbox. The helicopter sustained substantial damage to the main rotor blades and fuselage after the second contact.

Analysis

Primary failure mode
Loss of control
First missed decision gate
Pilot could have avoided maneuvering near power lines during application.

NTSB coding

Evidence available

  • 2 docket documents
View NTSB final reportView NTSB docket

Docket documents2