BOMBARDIER INC CL-600-2B1 near Atlanta, GA — 2009-06-11
- Date
- 2009-06-11
- Location
- Atlanta, GA, USA
- Airport
- ATL
- Aircraft
- BOMBARDIER INC CL-600-2B1
- Registration
- N857AS
- Category
- Airplane
- Highest injury
- None
- Fatalities
- 0
- Phase of flight
- Approach
Probable cause
The failure of the left main landing gear to extend due to high levels of particulate contamination in the hydraulic fluid.
NTSB narrative
While configuring the airplane for landing, the left main landing gear light indicated that it was not down and locked. The flight crew accomplished the landing gear abnormal procedures, including recycling the landing gear once. The left main gear continued to indicate unsafe, and the captain landed the airplane. After touching down on the right main and the nose gear, the captain used right aileron to keep the left wing up as long as possible. The left wing eventually dropped to the runway and the airplane came to a stop at the runway’s left edge. During recovery of the airplane, the left main gear was partially extended, and no physical obstructions were observed that would prevent the gear from extending. Loosening a hydraulic line to the left main gear actuator allowed the gear to fall into the extended and locked position. The airplane was examined and the landing gear was cycled numerous times using the normal and alternate extension methods. The examination failed to duplicate the incident conditions; the gear extended and retracted normally without hesitation or binding. All major components of the main landing gear system, including the left main landing gear, left gear door, hydraulic pumps, valves and actuators were examined at the manufacturers’ facilities. Although some minor anomalies were noted, no evidence was found to explain the failure of the gear to extend. Analysis of fluid from the numbers 2 and 3 hydraulic systems revealed that the fluid exceeded the maximum particle contamination limits. The system 3 sample also contained metallic particles. Hydraulic system 3 powers gear extension and retraction. After the incident, the operator enhanced its maintenance procedures for testing hydraulic fluid to include contamination. The operator also added verbiage to its pilot procedures to further explain that, in certain cases, it is appropriate to make several attempts at normal gear extension and provided more explanation and guidance regarding the use of the back-up (freefall) system.
Analysis
- Primary failure mode
- Mechanical failure
- First missed decision gate
- Captain could have opted for a go-around earlier to reassess landing gear situation.
NTSB coding
- Landing gear collapse · Landing-flare/touchdown
Evidence available
- CVR
- FDR / data
- Photos
- 35 docket documents
Docket documents35
- Cockpit Voice Recorder 12 - Specialist's Summary Reportcvr
- Flight Data Recorder 10 - Attachment 1 - Tabular Data (.csv file)fdr
- Flight Data Recorder 10 - Specialist's Factual Reportfdr
- Pilot/Operator Aircraft Accident Report, NTSB Form 6120.1form
- Crew Statements Provided by ASAinterview
- Statement of Party Representatives to NTSB Investigationinterview
- ASA Hydraulic Fluid Test Proceduresother
- Excerpts - Aircraft Maintenance Logother
- Excerpts - CRJ200 QRHother
- Runway Diagrams Provided by ATL Airport Operationsother
- Photo 1: Runway Scars with N857AS in Background (NTSB Digital Photo)photos
- Photo 2: N857AS, Frontal View (NTSB Digital Photo)photos
- Photo 3: View from Behind Left Wing (NTSB Digital Photo)photos
- Photo 4: Left Main Landing Gear, Prior to Aircraft Recovery (NTSB Digital Photo)photos
- Photo 5: Left Main Landing Gear as Aircraft is Raised with Air Bags (NTSB Digital Photo)photos
- Photo 6: Left Main Landing Gear as Aircraft is Raised with Air Bags (NTSB Digital Photo)photos
- Photo 7: Aircraft on Jacks after Recovery to Hangar (NTSB Digital Photo)photos
- Photo 8: Damage to Left Main Outboard Tire and Wheel (NTSB Digital Photo)photos
- Bombardier LM Gear Door Examination Reportreport
- Briem Hydraulic Fluid Test Reportreport
- Circor Relief Valve Test Reportreport
- Crissair Check Valve Test Reportreport
- Eaton Examination Report - AC Motorpump #1report
- Eaton Examination Report - AC Motorpump #2report
- Eaton Examination Report - AC Motorpump #3report
- Eaton Examination Report - Engine-driven Motorpumpreport
- Excerpts - Messier-Dowty Landing Gear Components Examination Reportreport
- Exxocare Hydraulic Fluid Reportreport
- Lee Company High Watt Jet Reportreport
- Parker Miniature Restrictor Check Valve Reportreport
- Pneudraulics Priority Valve Test Reportreport
- Solutia Hydraulic Fluid Test Reportreport
- Tactair Report - By-Pass and Runaround Valvereport
- Tactair Report - Main LG Selector Valvereport
- Tactair Report - Manual LG Selector Valvereport
Related mishaps
- MCCAA ROBERT T AVID/KITFOX FLYER
2025-09-28 · Oakland, PA
- CESSNA 182F
2025-06-29 · Nephi, UT
- DIAMOND AIRCRAFT IND INC DA20-C1
2024-10-02 · Mesa, AZ
- CESSNA 180A
2024-04-04 · Nordman, ID
- BEECH C23
2024-01-01 · Mansfield, LA
- CESSNA T210M
2023-08-21 · Napa, CA