Pilot Debrief

ENSTROM 280FX near Corpus Christi, TX — 2012-04-03

Final reportCEN12LA228
Sign in to save
Date
2012-04-03
Location
Corpus Christi, TX, USA
Airport
CRP
Aircraft
ENSTROM 280FX
Registration
N3042D
Category
Helicopter
Highest injury
Minor
Fatalities
0
Phase of flight
Hover

Probable cause

The failure of the bolt that retained the clutch drive rod end, which resulted in a loss of main rotor drive and a subsequent hard landing.

NTSB narrative

After an uneventful flight, the pilot slowed the helicopter into a stable hover about 15 feet above the landing point. Although the engine continued to operate, the main rotor rpm suddenly decayed and the helicopter landed hard. The pilot, who had over 5,600 flight hours in helicopters, stated that there was no warning before the loss of main rotor drive. The helicopter was in a position whereby power to the rotor system was essential to conducting a safe landing. Examination of the helicopter revealed that the bolt that retains the clutch drive rod end in the clutch pivot fork had sheared, resulting in the clutch disengaging. Once the clutch disengaged, there was no drive to the rotor system, and the helicopter's descent could not be arrested. With the exception of the failed bolt, examination of the entire drive system did not show any preexisting mechanical malfunction or abnormalities that would have precluded normal operation. The helicopter had operated about 1,350 hours since it was new, and the retaining bolt was the original installation. The reason for the failure of the bolt could not be determined.

Analysis

Primary failure mode
Mechanical failure
First missed decision gate
Pilot could have checked mechanical components before flight.

NTSB coding

Evidence available

  • Photos
  • 7 docket documents
View NTSB final reportView NTSB docket

Docket documents7

Related mishaps