Cessna R182 near Florence, SC — 2018-08-09
- Date
- 2018-08-09
- Location
- Florence, SC, USA
- Airport
- KFLO
- Aircraft
- Cessna R182
- Registration
- N1693R
- Category
- Airplane
- Highest injury
- None
- Fatalities
- 0
- Phase of flight
- Approach
Probable cause
The pilot's failure to comply with emergency procedures in the pilot's operating handbook, resulting in the collapse of the main landing gear during landing. Contributing to the accident was the pilot's failure to address the low battery voltage before departure.
NTSB narrative
Before departure on the personal flight, the private pilot reported that the engine had to be started using an auxiliary power supply because the battery was dead; however, he did not determine the reason for the dead battery. After the engine was started, he reported normal electrical system indications. About 10 minutes into the 20-minute flight, the pilot noticed that the electric fuel gauges were reading zero and the ammeter was showing a discharge. He did not consult or comply with emergency procedures from the pilot's operating handbook (POH) for a discharging ammeter and continued to his destination, where he attempted to extend the landing gear using the normal system; however, there was no down-and-locked indication. He confirmed visually that the nose landing gear was down and locked; he performed a fly-by of the air traffic control tower, was informed that the landing gear appeared to be down, and returned for landing. After touchdown, both main landing gear collapsed, the airplane began to veer to the left, and the left wing and horizontal stabilizer contacted the runway. The airplane came to rest in the grass off the left side of the runway. Postaccident examination and operational testing of the normal and emergency landing gear extension and indicating systems revealed no evidence of preimpact failure or malfunction that would have precluded normal operation. Had the pilot shed unnecessary electrical load per the POH when he first noticed the discharging state or pumped the landing gear down using the emergency gear extension mechanism, it is likely that the landing gear would have extended and locked into position. The reason for the electrical system failure was not investigated.
Analysis
- Primary failure mode
- Fuel management
- First missed decision gate
- Pilot did not perform emergency procedures for electrical fault after fuel gauge showed zero.
NTSB coding
Evidence available
- 6 docket documents
Docket documents6
Related mishaps
- CESSNA P210
2024-05-16 · Daggett, CA
- BEECH 95-B55 (T42A)
2022-11-03 · Athens, GA
- AGUSTA AW139
2022-09-24 · Houma, LA
- KUYKENDALL CHARLES LANCAIR IV
2021-07-28 · Indian Springs, NV
- MOONEY M20F
2021-07-22 · New Albany, MS
- PIPER PA32R
2020-11-20 · Canon City, CO